[Wait for signal] intermediate event

The [Wait for signal] intermediate event (Fig. 1) is used for resuming a business process by events that occur in other processes or whenever a specific record is modified or deleted in Creatio.

Fig. 1 [Wait for signal] intermediate event

scr_process_designer_catch_signal_event.png 

For example, a business process can wait until the user starts working on an activity (its status is changes to “In progress”) before proceeding to the next step.

[Wait for signal] intermediate event operation

Activation

After the element incoming flow is activated, the [Wait for signal] intermediate event waits for the corresponding signal. Depending on the element mode, the [Wait for signal] element will wait for one of the following events:

  • A corresponding signal is generated by the [Throw signal] intermediate event in any other business process.

  • A corresponding Creatio record is modified or deleted.

Execution

When the expected signal is generated by a [Throw signal] event, or the monitored record is modified or deleted, the [Wait for signal] element activates its outgoing flows and enables the execution of the other actions in the business process.

[Wait for signal] intermediate event parameters

Which type of signal is received?

Choose which signal activates the event:

  • Select “Custom signal” if the event is activated by a [Throw signal] intermediate event in any business process (the current business process or any other).

  • Select “Record signal” if the event is activated whenever an object record is modified or deleted in Creatio.

The selected option determines what following parameters will appear in the element setup area.

Run following elements in the background

Select this checkbox, if you want any “User action” elements activated with the outgoing flows of the current element to run “in the background”. When process elements are executed in the background, their loading mask is not displayed, no windows pop up for the user, etc. The user will be able to interact with the elements via the [Business process tasks] tab of the communication panel.

Custom signal mode parameters

In the “Custom signal” mode, the [Wait for signal] event is triggered by a [Throw signal] intermediate event from another process(es).

Signal

Enter a signal value. Make sure that the field is populated with the custom-generated signal name matching the name of the signal specified in the [Which signal is generated?] field of the [Throw signal] element (Fig. 2 and Fig. 3) in the corresponding process. Such signal name can be generated by user at random.

Fig. 2 Specifying the name of a signal that activates the [Wait for signal] intermediate event in the “Custom signal’ mode

scr_chapter_process_designer_wait_signal_example00032.png 

Fig. 3 Example of a [Throw signal] element that generates the corresponding signal

scr_chapter_process_designer_throw_signal_example100033.png 

Record signal mode parameters

In the “Record signal” mode, the [Wait for signal] element is triggered when an object record is modified or deleted in Creatio.

Record Id

Specify the record that triggers the [Wait for signal] element. Learn more about how to work with parameter values in a separate article. For example, if the process waits for a signal from an activity record, specify the unique identifier of an activity.

Object

Select the object whose record generates the signal. For example, to catch a signal from an activity record, select the “Activity” object. Note that if you specify the [Record Id] field value via a corresponding lookup, the [Object] field value will be populated automatically with the name of the corresponding object.

Which event should trigger the signal?

Choose whether the element should activate when the record is modified or deleted:

  • Select “Record modified” if editing the specified object record activates the signal.

  • Select “Record deleted” if deleting the specified object record activates the signal.

Changes expected

The field becomes available when the “Record modified” is selected in the [Which event should trigger the signal] field.

  • Select “In any field” to run business process automatically, upon changes in any field of the selected object record.

  • Select “In any of the selected fields” to run business process automatically, upon changes in specific fields only. Click [+Add column] and select the needed fields. For example, if the signal can be activated only if an activity status is modified, add the [Status] column. If a change occurs in a column that has not been added, the process will not start.

The record must meet the filter conditions

If the record does not meet the filter conditions, the element will not be activated. For example, the signal should only be activated if the status of an activity is set to “Completed”. If the filter is not set, the signal will be activated on any modification of record (for “Record modified” mode) or on deletion of any record (for “Record deleted” mode).

[Wait for signal] intermediate event outgoing parameters

The [Wait for signal] intermediate event outgoing parameters include:

RecordId

The parameter contains the identifier of the modified/deleted record that triggered the signal. Note that the data of a deleted record can only be read if the process is not run in the background mode.

This parameter is similar to the [Unique identifier of record] parameter of the [Signal] start event.

Next

[Throw signal] intermediate event

[Throw message] intermediate event

[Wait for timer] intermediate event

[Start timer] event

[Signal] start event

Did you find this information useful?

How can we improve it?