Studio Creatio
PDF
This documentation is valid for Creatio version 7.16.0. We recommend using the newest version of Creatio documentation.

How to integrate with CallWay

In Creatio, the CallWay integration functionality requires a separate license. You need to generate a license request, send it to our service team, upload the received license file into the system and finally, distribute the licenses between the users.

Note

See more details about licensing in the “Software licensing” and “License distribution” articles.

The integration is only possible if complete preliminary CallWay setup was performed by the phone integration administrator.

If you set up the telephony for a development environment application, locate TMS on a separate node instead of the Creatio application server. To ensure the fault tolerance of your phone integration, we recommend setting up at least two nodes with TMS, as well as a balancer that would redirect users in case of lost connection with one of the nodes.

Setting up Creatio messaging service

The messaging service allows you to connect Creatio to the phone integration using the integration protocol to connect to CallWay and distributing the call events between Creatio users.

1.Contact Creatio support to receive the installation files. Run the received .MSI file on the message exchange server and proceed with the installation.

Attention

.NET Framework of version 4.7.2 or higher should be installed on the server where you configure the Creatio Messaging Service.

2.Specify the CallWay server address in the “Terrasoft.Messaging.Service.exe.config” file:

<callway url="CallWay_server_address" login="XXX" password="XXX" port="34600" restoreConnectionInterval="2000" />

See the list of configuration file parameters in the table below.

Parameter caption

Parameter function

url

CallWay server IP address parameter.

login

Integration protocol login and password.

password

port

Integration protocol port. By default, “34600”.

restoreConnectionInterval

The time interval to reconnect the integration messaging service to the CallWay phone integration server, if a failure occurs. The value is specified in milliseconds and is “2000” - by default.

Setting up message exchange library

Message exchange library selection and setup is performed once by the system administrator.

1.Open the system designer by clicking btn_system_designer00009.png in the top right corner of the application window.

2.Click the [System settings] link in the [System setup] block (Fig. 1).

Fig. 1 Opening the [System settings] section

scr_chapter_telephony_setup_link_system_settings00010.png 

3.Specify the message exchange library. To do this, open the “Default messages exchange library” system setting. On the system setting page:

a.Populate the [Value by default] field by selecting the "Phone integration library based on Callway protocol” value;

b.Click [Save].

4.Specify the message service connection parameters. To do this, open the “Message exchange server” system setting. On the system setting page:

a.In the [Default value] field, specify the message exchange network address in the following format: “ws://0.0.0.0:2013”, if your website is available by the http protocol, or “wss://0.0.0.0:2013”, if your website is available by the https protocol, where:

“0.0.0.0” – IP address that your Creatio users use to access your message exchange server.

“2013” – the port used by default for connecting to the messaging service. You can change the port number in the “Terrasoft.Messaging.Service.exe.config” file.

Note

If your website is available by HTTPS and secure (WWS) connection is used for WebSockets, you will need to install a security certificate on the message exchange server and specify it in the configuration files of the message service. For more information about the setup process, contact Creatio technical support at support@creatio.com.

b.Click [Save].

Setting CallWay parameters

These settings should be applied for each Creatio user who received CallWay integration license. Use the user login credentials to access the system.

1.Open the user profile page by clicking the [Profile] image button on the main page of the application.

2.Click the [Call Center parameters setup] button.

3.On the opened page, populate the required values:

a.[Disable Contact Centre integration] – the checkbox allows you to disable Creatio integration with the telephony. The call button will not be displayed on the communication panel of the application.

b.[Agent internal number] – CallWay user phone number.

c.[Routing rule] – specify the routing rule if it is required for the CallWay configured server.

d.[Use CallWay client] – select the checkbox if an employee uses CallWay internal client. While using the CallWay internal client, the answer button in the application becomes available.

e.[Enable debugging] – the checkbox allows you to display troubleshooting information within the browser console. This troubleshooting information can be used when the phone integration runs into problems and the customer addresses the service team.

4.Click [Save].

5.Refresh the browser page to apply the changes.

See also

Configure WSS connection for the phone service

Software licensing

License distribution

Did you find this information useful?