Skip to main content
Version: 8.0

NLog

Level: intermediate

We recommend enabling logging to verify that the new functionality operates as expected. For optimal performance, enable logging only while testing and debugging Creatio. Creatio can log all primary operations. This is achieved using the NLog library, a free .NET logging library that supports routing features and log management. NLog is suitable for any Creatio instance regardless of size or complexity.

The library lets you perform the following actions:

  • handle diagnostic messages sent in any .NET language
  • enrich logs with contextual data
  • format logs based on user preferences
  • send logs to one or more message receivers, such as a file or database

Learn more about the NLog on the GitHub website.

Set up logging for Creatio on-site

Creatio logs events for the loader and Default configuration separately.

You can set up logging for Creatio on-site in the following ways:

  • via the configuration file
  • via the LoggingConfiguration configuration object

View an example that sets up logging in a separate article: Implement a modal box.

Set up logging for Creatio on-site via the configuration file

1. Set the path to the log configuration file

You can set up logging in the following configuration files of the ..\Terrasoft.WebApp directory:

  • nlog.config
  • nlog.targets.config

Set the path to the nlog.config file in the ..\Terrasoft.WebApp\Web.config configuration file.

Example of the nlog.config file
<common>
<logging>
<factoryAdapter type="Common.Logging.NLog.NLogLoggerFactoryAdapter, Common.Logging.NLog45">
<arg key="configType" value="FILE" />
<arg key="configFile" value="~/nlog.config" />
</factoryAdapter>
</logging>
</common>

2. Specify the log receivers

Log receivers display, store and transfer the log messages to other receivers.

Log receivers have the following types:

  • Receivers that receive and handle messages
  • receivers that buffer or forward messages to another receiver

Specify the log receivers in the <target> XML element of the ...\Terrasoft.WebApp\nlog.targets.config file.

The configuration attributes of log receivers are as follows:

  • name. Receiver name.

  • xsi:type. Receiver type. Available values: "File," "Database," "Mail."

  • fileName. Log file and path to the log file. The log file location depends on the values of Windows system variables.

    [TEMP]\Creatio\Site_[SiteId][ApplicationName]\Log[DateTime.Today]
    [TEMP]\Creatio\Site_[SiteId][ApplicationName][ConfigurationNumber]\Log[DateTime.Today]
  • [TEMP]. Base directory. By default, IIS uses the C:\Windows\Temp directory. Visual Studio (IIS Express) uses the C:\Users[User name]\AppData\Local\Temp directory.

  • [SiteId]. Website number. For IIS, find the website number in the advanced website settings. For Visual Studio, the number is 2.

  • [ApplicationName]. Creatio name.

  • [ConfigurationNumber]. Configuration number. The number for the Default configuration is usually 0.

  • [DateTime.Today]. Log date.

  • layout. Template for populating the log file.

    Example of the nlog.targets.config file
    <target name="universalAppender" xsi:type="File"
    layout="${DefaultLayout}"
    fileName="${LogDir}${LogDay}${logger:shortName=True}.log" />

Learn more about log receivers in the official NLog documentation.

3. Define the log rules

You can define the log rules in the nlog.config file.

The configuration attributes of log rules are as follows:

  • name. Log name.

  • minlevel. Minimum logging level. The default logging level for Creatio components is set to ensure the highest performance.

    Available logging levels in ascending priority:

    • Trace. Log all events during setup. Set the initial and final methods.
    • Debug. Log all events during debugging.
    • Info. Log regular Creatio activity.
    • Warn. Log warnings. Creatio continues to operate after logging.
    • Error. Log errors that might crash Creatio.
    • Fatal. Log errors that inevitably crash Creatio.
    • Off. Disable logging.
  • maxlevel. Maximum logging level.

  • level. Log events of a specific logging level.

  • levels. Log events of multiple logging levels, separated by commas.

  • writeTo. The name of the log receiver.

  • final. Whether to handle subsequent rules.

  • enabled. Disable the log rule (set to false) without deleting it.

  • ruleName. The log rule ID.

NLog handles logging rule attributes in the following order:

  1. level
  2. levels
  3. minlevel and maxlevel

If minLevel = "Warn" level = "Info", only the Info logging level is used, because the handling priority of the level attribute is higher than minLevel.

Example of a log rule that writes a log to the database
<logger name="IncidentRegistration" writeTo="AdoNetBufferedAppender" minlevel="Trace" final="true" />

Set up logging for Creatio on-site via the LoggingConfiguration configuration object

  1. Create a LoggingConfiguration object that describes the configuration.
  2. Create the log receivers.
  3. Set up the properties of the log receivers.
  4. Define the logging rules using LoggingRule objects.
  5. Add the logging rules to the LoggingRules configuration objects.
  6. Activate the configuration. To do this, specify the created configuration object in LogManager.Configuration.

Set up logging for Creatio in the cloud

To set up logging for Creatio in the cloud, contact Creatio support.

Important

It is impossible to add an additional log receiver when setting up logging for Creatio in the cloud.